ASAP2 STANDARD PDF

and communication methods from the ASAP2 description file, and are Via the ASAP1b interface the standard connection of the control units. ASAP2 Lib is a powerful and easy-to-use function library, which you can use for reading and writing standardized ECU description files in ASAP2 format for your . The ASAP2 Tool-Set consists of 6 programs for creating, checking, updating, merging, A2L files that are not standard-conformant can also be read-in using the.

Author: Daigar Nit
Country: Spain
Language: English (Spanish)
Genre: Software
Published (Last): 19 December 2004
Pages: 229
PDF File Size: 12.23 Mb
ePub File Size: 13.76 Mb
ISBN: 552-6-55006-791-7
Downloads: 23101
Price: Free* [*Free Regsitration Required]
Uploader: Arashirg

ECU calibration with ASAP2Demo/ASAP2Library

This method is equivalent to enumerated types in assp2 C programming language. The standard is also used in adjacent industries such as in train- and shipbuilding. If the memory address attribute is unknown before code generation, the code generator inserts ECU Address placeholder text in the generated ASAP2 file.

Most of the production code generators for embedded software automatically generate a2l-files along with C-code sources. Axis points are not stored in ECU memory. The prototype also specifies whether parameters and aggregated keywords are mandatory or optional, their multiplicity and use of delimiters.

Allows to specify a project number and an ECU software version, for which the a2l-file is compatible with. Without standardization, the creation and maintenance of such description files could easily become a major time and cost factor of the overall development process.

Furthermore, it is common practice to place the interface description i. Specifies the properties of an axis that belongs to a tunable curve, map or cuboid.

At the beginning of an a2L-file, the version stnadard keyword: Specifies position and datatype of the distance i. Can be used to define measurement objects, which are part of a structure.

  DIEGO LOPEZ MEDINA TEORIA IMPURA DEL DERECHO PDF

This page has been translated by MathWorks. Use the Model Data Editor to configure the remaining properties as desired for each data item. The following table provides a typical interpretation of the data types as used in the automotive industry. The standard is also used by in-vehicle data loggers and diagnostic tools. You apply a custom storage class that causes the code generator to generate a macro or non-addressable variable. The standard is used furthermore in other tools in the MCD area, such as data loggers, diagnostic tools, rapid control prototyping systems and automated calibration and testing systems.

Other keywords underneath a keyword create a hierarchical structure of keywords similar to an aggregation in XML. This inclusion was a deliberate decision to keep all information to describe and access ECU data in one location. Each module represents one ECU. ASAP2 is a non-object-oriented description of the data used for measurement, calibration, and diagnostic systems. The standard is technology and vendor independent. They are described by input-output value pairs, i.

Can be used for defining multiple axis objects of the same type.

ASAP2 is a non-object-oriented description of the data used for measurement, calibration, and diagnostics systems. Axes contain the sample point values for curves and maps. Don’t have an account? They are aggregated by primary keywords.

Export ASAP2 File for Data Measurement and Calibration – MATLAB & Simulink

Used to resolve near-pointers in record layouts or to select the data set among several variant data sets. Shall be used only, if linear or rational functions are not sufficient. The a2l-file consists of four structural qsap2 Bit masks and bit operations can be applied to the measurement. Verbal conversion tables are used to convert internal ECU values into human-readable strings.

  CICLO DE VIDA DE ENDOLIMAX NANA PDF

Generic Real-Time Target grt. Reference to a tunable parameter, which selects the active variant by its value. Input and output objects cannot contain measurement objects.

Axis specific to one table with calculated axis points. You can run an interactive example of ASAP2 file generation. Specifies a conversion formula to calculate the ECU-internal value from the physical value. Single line comments start with a double forward-slash i. If the memory address attribute is unknown before code generation, the stansard generator inserts ECU Address placeholder text in the generated ASAP2 file, as shown in the example below.

Also, you can use data objects from data classes that are derived from Simulink. The downloadable archive contains an a2l-file and a referenced transformer-DLL for demonstration purposes. Standarf MCD standard provided the way to abstract aszp2 calibration from the physical memory locations.

ASAM MCD-2 MC

Sttandard standard includes the following deliverables: The parameters of a keyword contain the values of the data model. Use any storage class or custom storage class other than AutoFileScopeor, if you set the default storage class of the stahdard data category to Default in the Code Mapping Editor the default settingModel default. Reference to a memory segment in case the address is not unique, e. Secondary keywords may actually span across several more levels.

Relevant information such as detailed descriptions of calibration and measurement variables is included.